You're viewing a public project in read-only mode. Sign in to edit

Overall Evaluation — Alcalá de Henares / Municipal WW

Scoped to one remediation method. Before = baseline samples matching the method's sample type; a phase the method doesn't have shows as “no data”.

Overall assessment

Site OK — routine monitoring based on the latest sampling date: 1.4.2026 (After Remediation)

Phase-by-phase verdicts

Worst result per domain on each sampling date, grouped by remediation phase.

Domain Before Remediation During Remediation After Remediation Trend
8.3.2026
water
1.4.2026
water
Ecotoxicology D
Daphnids
· B
Lettuce aquatic
Improving
Chemistry
0 high · 0 risk · 0 ok
· ·
Supportive methods provisional Improving
Shannon index 3.23 · 3.32
Simpson index 0.82 · 0.82
Respiration · · ·
Nitrification Conf · Conf

Each column is one sampling date; a cell shows the worst result recorded across that date's samples. A phase with no samples for the selected method shows as “—”. Supportive methods are shown for reference and do not yet move the overall stance.

Supportive methods evaluation

Sample Type Method (phase) Diversity (H′ / 1−D) Nitrification Respiration Conformity
Untreated Metfilter Effluent water Before Remediation H′ 3.23 · 1−D 0.82
8.4%
Within ±20%
Conforming
Conforming
Electro-Fenton + Bioreactor treatment water After Remediation H′ 3.32 · 1−D 0.82
-11.6%
Within ±20%
Conforming
Conforming
Time zero — before remediation
Sample Type Shannon (H′) Simpson (1−D)
Untreated Metfilter Effluent water 3.23 0.82
During & after remediation
Sample Type Shannon (H′) Simpson (1−D)
Electro-Fenton + Bioreactor treatment water 3.32 0.82

Biodiversity is read as a trend — rising Shannon / Simpson from the before stage onward indicates recovery. Expected levels per phase are in admin → Biology phase profiles.

Sample Type Phase QR AHB (CFU/g) Evaluation Conformity
Untreated Metfilter Effluent water Before Remediation
Electro-Fenton + Bioreactor treatment water After Remediation

QR ≤ 0.5 acceptable. QR > 0.5 → check AHB: ≥ 10³ CFU/g = bioremediation not suitable (strongly inhibited); < 10³ = not suitable without microbial augmentation (bioaugmentation, repeat measurements, assess inhibition).

Sample Type Phase Inhibition / stimulation Evaluation Conformity
Untreated Metfilter Effluent water Before Remediation 8.4% Within ±20% Conforming
Electro-Fenton + Bioreactor treatment water After Remediation -11.6% Within ±20% Conforming

The inhibition or stimulation of nitrification must not exceed ±20%. Values beyond this indicate a significant effect of the sample on the nitrifying microbial community.

Visual overall assessment

Each domain across the sampling timeline — colour shows the result; reading left→right shows the trend.

Ecotoxicology
Before Remediation During Remediation After Remediation
8.3.2026
water
1.4.2026
water
A. fischeri 15 A · A
A. fischeri 30 A · A
Algae A · A
Daphnids D · A
Lettuce aquatic B · B
Worst (per date) D · B

Result: Improving across phases

Chemistry
Before Remediation During Remediation After Remediation
8.3.2026
water
1.4.2026
water
Others · ·
Worst (per date) · ·

Result: Not enough phases to compare

Supportive methods
Before Remediation During Remediation After Remediation
8.3.2026
water
1.4.2026
water
Shannon index 3.23 · 3.32
Simpson index 0.82 · 0.82
Respiration · · ·
Nitrification Conf · Conf

Result: Biodiversity rising across phases

Overall — before · during · after combined
Site OK — routine monitoring

Conclusion

Auto-generated draft

Based on the most recent data (After Remediation) for Alcalá de Henares – Municipal WW, the site is assessed as: Site OK — routine monitoring. Chemistry: no classified measurements available for this phase. Ecotoxicology: dominant category is B (Low toxicity). The most sensitive organism is Lettuce aquatic. Across the recorded phases, ecotoxicity is improving across phases. Recommendation: the site is within acceptable limits — continue with routine monitoring to confirm the favourable condition remains stable. Biology / supportive methods (provisional): biodiversity rising across phases. These indicators are shown for reference and do not yet affect the overall stance.